ConstantID

Reduced Planck constant

UniversalAdoptedExact

ℏ = 1.054 571 817… × 10−34 J s

Value
1.054 571 817… × 10−34 J s
Standard uncertainty
exact
Relative uncertainty
exact
Status
Exact since the 2019 SI redefinition
Symbol
ℏ
Source
CODATA 2022 via NIST · NIST entry

NIST prints this exact value cut to 10 digits. ConstantID recomputes it from the defining constants: 1.054 571 817 646 156 391 262 428 0033 × 10−34…

Use in a calculation

# reduced Planck constant, CODATA 2022 (NIST)
hbar = 1.0545718176461563912624280033022807e-34  # J s, exact

# SciPy: scipy.constants.physical_constants['reduced Planck constant']

What it is

The Planck constant divided by 2π, often called h-bar. It is the natural unit of angular momentum in quantum mechanics: the spin of an electron is ħ/2, and the uncertainty principle sets Δx·Δp ≥ ħ/2. Because h is exact, ħ is exact too, but it has infinitely many digits.

It is built only from constants that have exact values since 20 May 2019, so it is exact too; CODATA 2018 was the first adjustment to list it that way.

Equations

  • ℏ=h2πdefinition
  • ΔxΔp≥ℏ2uncertainty principle
  • E=ℏωenergy and angular frequency

In other units

UnitValue
CGS (cm2 g s−1)1.054 571 818 × 10−27exact

Converted with ConstantID's unit table; digits are rounded to the precision of the value, and a long exact value is rounded only for display.

Reduced Planck constant ħ in eV·s, MeV·fm and other units →

How the value changed, 1998–2022

Each point is one CODATA adjustment, plotted as its difference from the 2022 value; the bars show one standard uncertainty (an arrowhead means the bar runs off the chart). Diamonds mark adjustments in which the value was exact.

reduced Planck constant: CODATA values 1998–2022 relative to the 2022 value, in parts per billion, with one-standard-uncertainty bars−300−200−1000+100+200+300parts per billion1998200220062010201420182022

Relative uncertainty

reduced Planck constant: relative standard uncertainty in each CODATA adjustment, logarithmic scale10⁻⁸10⁻⁷10⁻⁶199820022006201020142018exact2022exact
CODATAValue (uncertainty)Relative uncertaintyChange from previous
20221.054 571 817… × 10−34exact exact
20181.054 571 817… × 10−34exact +1.3 σ of 2014
20141.054 571 800(13) × 10−341.2 × 10−8 +1.6 σ of 2010
20101.054 571 726(47) × 10−344.5 × 10−8 +1.8 σ of 2006
20061.054 571 628(53) × 10−345.0 × 10−8 −0.3 σ of 2002
20021.054 571 68(18) × 10−341.7 × 10−7 +1.0 σ of 1998
19981.054 571 596(82) × 10−347.8 × 10−8

“Change from previous” is the shift in the value divided by the standard uncertainty of the previous adjustment. Earlier values are converted into the current unit where NIST changed it (for example J s to J Hz⁻¹).

Related constants